{"id":9640,"date":"2025-09-01T13:30:31","date_gmt":"2025-09-01T13:30:31","guid":{"rendered":"https:\/\/www.climabarn.com\/?page_id=9640"},"modified":"2026-04-01T10:14:09","modified_gmt":"2026-04-01T10:14:09","slug":"ventilation-in-reclyning-area","status":"publish","type":"page","link":"https:\/\/www.climabarn.de\/en\/barn-ventilation\/ventilation-in-reclyning-area\/","title":{"rendered":"Reclyning Area"},"content":{"rendered":"<p>Cows need cool, calm conditions to lie down and ruminate properly. Our ventilation system ClimaBarn ensures consistent airflow along the beds \u2013 reducing heat stress, boosting comfort, and supporting optimal milk yields.<br \/>\nDepending on the season, the targeted air reaches each cows\u2019 body at optimum air velocity for comfort and cooling. The cubicles become welcoming and are evenly occupied improving and easing the cow flow. <\/p>\n<p>How does ventilation system help cows rest more comfortably in the lying area?<br \/>\nClimaBarn distributes fresh air evenly across all cubicles, preventing hot spots and stagnant pockets. Uniform airflow keeps the lying area cooler, reducing heat stress and encouraging cows to lie longer, which is directly linked to higher milk production.<\/p>\n<p>What specific airflow is required in the reclining area?<br \/>\nThe reclining area is where cows spend up to 12-14 hours per day resting and ruminating, so airflow must be steady and evenly distributed. The goal is to prevent heat stress that disturbs resting cows.<br \/>\n\u2022 Air exchange rates: About 4-6 air changes per hour in winter (to control humidity and ammonia without chilling) and up to 40-60 air changes per hour in summer to keep temperatures down.<br \/>\n\u2022 Air speed at cow level: Ideally 0.5-1.0 m\/s in cooler months (barely perceptible movement) and up to 2.0-2.5 m\/s in hot weather to provide a cooling wind-chill effect.<br \/>\n\u2022 Even distribution: Fabric ducts are especially effective in the lying area because they eliminate hot spots and stagnant zones, d<span class=\"cf0\">elivering directly the fresh air across all cubicles rather than just near fans or openings. <\/span><!--EndFragment --><\/p>\n","protected":false},"excerpt":{"rendered":"<p>Cows need cool, calm conditions to lie down and ruminate properly. Our ventilation system ClimaBarn ensures consistent airflow along the beds \u2013 reducing heat stress, boosting comfort, and supporting optimal milk yields. Depending on the season, the targeted air reaches each cows\u2019 body at optimum air velocity for comfort and cooling. The cubicles become welcoming [&hellip;]<\/p>\n","protected":false},"author":8,"featured_media":9618,"parent":9043,"menu_order":7,"comment_status":"closed","ping_status":"closed","template":"","meta":{"inline_featured_image":false,"footnotes":""},"class_list":["post-9640","page","type-page","status-publish","has-post-thumbnail","hentry"],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v27.6 - https:\/\/yoast.com\/product\/yoast-seo-wordpress\/ -->\n<title>Reclyning Area | ClimaBarn English<\/title>\n<meta name=\"description\" content=\"ClimaBarn ventilation in reclyning area ensure cool, draft-free airflow in cow farms, boosting comfort and supporting higher milk yields.\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/www.climabarn.de\/en\/wp-json\/wp\/v2\/pages\/9640\/\" \/>\n<meta property=\"og:locale\" content=\"en_US\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Reclyning Area - ClimaBarn English\" \/>\n<meta property=\"og:description\" content=\"ClimaBarn ventilation in reclyning area ensure cool, draft-free airflow in cow farms, boosting comfort and supporting higher milk yields.\" \/>\n<meta property=\"og:url\" content=\"https:\/\/www.climabarn.de\/en\/barn-ventilation\/ventilation-in-reclyning-area\/\" \/>\n<meta property=\"og:site_name\" content=\"ClimaBarn English\" \/>\n<meta property=\"article:publisher\" content=\"https:\/\/www.facebook.com\/FabricAir\/\" \/>\n<meta property=\"article:modified_time\" content=\"2026-04-01T10:14:09+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/www.climabarn.de\/en\/wp-content\/uploads\/sites\/22\/2025\/08\/AdobeStock_899378495-scaled-e1756788336307.webp\" \/>\n\t<meta property=\"og:image:width\" content=\"2560\" \/>\n\t<meta property=\"og:image:height\" content=\"1058\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/jpeg\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:site\" content=\"@FabricAir\" \/>\n<meta name=\"twitter:label1\" content=\"Est. reading time\" \/>\n\t<meta name=\"twitter:data1\" content=\"1 minute\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/www.climabarn.de\\\/en\\\/barn-ventilation\\\/ventilation-in-reclyning-area\\\/\",\"url\":\"https:\\\/\\\/www.climabarn.de\\\/en\\\/barn-ventilation\\\/ventilation-in-reclyning-area\\\/\",\"name\":\"Reclyning Area - ClimaBarn English\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/www.climabarn.com\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/www.climabarn.de\\\/en\\\/barn-ventilation\\\/ventilation-in-reclyning-area\\\/#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/www.climabarn.de\\\/en\\\/barn-ventilation\\\/ventilation-in-reclyning-area\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/www.climabarn.de\\\/en\\\/wp-content\\\/uploads\\\/sites\\\/22\\\/2025\\\/08\\\/AdobeStock_899378495-scaled-e1756788336307.webp\",\"datePublished\":\"2025-09-01T13:30:31+00:00\",\"dateModified\":\"2026-04-01T10:14:09+00:00\",\"description\":\"ClimaBarn ventilation in reclyning area ensure cool, draft-free airflow in cow farms, boosting comfort and supporting higher milk yields.\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/www.climabarn.de\\\/en\\\/barn-ventilation\\\/ventilation-in-reclyning-area\\\/#breadcrumb\"},\"inLanguage\":\"en\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/www.climabarn.de\\\/en\\\/barn-ventilation\\\/ventilation-in-reclyning-area\\\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"en\",\"@id\":\"https:\\\/\\\/www.climabarn.de\\\/en\\\/barn-ventilation\\\/ventilation-in-reclyning-area\\\/#primaryimage\",\"url\":\"https:\\\/\\\/www.climabarn.de\\\/en\\\/wp-content\\\/uploads\\\/sites\\\/22\\\/2025\\\/08\\\/AdobeStock_899378495-scaled-e1756788336307.webp\",\"contentUrl\":\"https:\\\/\\\/www.climabarn.de\\\/en\\\/wp-content\\\/uploads\\\/sites\\\/22\\\/2025\\\/08\\\/AdobeStock_899378495-scaled-e1756788336307.webp\",\"width\":2560,\"height\":1058,\"caption\":\"A group of black and white dairy cows lies comfortably on a smooth concrete floor inside a spacious barn designed for livestock. The cows are dispersed in a neat row, highlighting their calm demeanor in the well-lit environment.\"},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/www.climabarn.de\\\/en\\\/barn-ventilation\\\/ventilation-in-reclyning-area\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/www.climabarn.de\\\/en\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Barn Ventilation\",\"item\":\"https:\\\/\\\/www.climabarn.de\\\/en\\\/barn-ventilation\\\/\"},{\"@type\":\"ListItem\",\"position\":3,\"name\":\"Reclyning Area\"}]}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"Reclyning Area | ClimaBarn English","description":"ClimaBarn ventilation in reclyning area ensure cool, draft-free airflow in cow farms, boosting comfort and supporting higher milk yields.","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/www.climabarn.de\/en\/wp-json\/wp\/v2\/pages\/9640\/","og_locale":"en_US","og_type":"article","og_title":"Reclyning Area - ClimaBarn English","og_description":"ClimaBarn ventilation in reclyning area ensure cool, draft-free airflow in cow farms, boosting comfort and supporting higher milk yields.","og_url":"https:\/\/www.climabarn.de\/en\/barn-ventilation\/ventilation-in-reclyning-area\/","og_site_name":"ClimaBarn English","article_publisher":"https:\/\/www.facebook.com\/FabricAir\/","article_modified_time":"2026-04-01T10:14:09+00:00","og_image":[{"width":2560,"height":1058,"url":"https:\/\/www.climabarn.de\/en\/wp-content\/uploads\/sites\/22\/2025\/08\/AdobeStock_899378495-scaled-e1756788336307.webp","type":"image\/jpeg"}],"twitter_card":"summary_large_image","twitter_site":"@FabricAir","twitter_misc":{"Est. reading time":"1 minute"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"WebPage","@id":"https:\/\/www.climabarn.de\/en\/barn-ventilation\/ventilation-in-reclyning-area\/","url":"https:\/\/www.climabarn.de\/en\/barn-ventilation\/ventilation-in-reclyning-area\/","name":"Reclyning Area - ClimaBarn English","isPartOf":{"@id":"https:\/\/www.climabarn.com\/#website"},"primaryImageOfPage":{"@id":"https:\/\/www.climabarn.de\/en\/barn-ventilation\/ventilation-in-reclyning-area\/#primaryimage"},"image":{"@id":"https:\/\/www.climabarn.de\/en\/barn-ventilation\/ventilation-in-reclyning-area\/#primaryimage"},"thumbnailUrl":"https:\/\/www.climabarn.de\/en\/wp-content\/uploads\/sites\/22\/2025\/08\/AdobeStock_899378495-scaled-e1756788336307.webp","datePublished":"2025-09-01T13:30:31+00:00","dateModified":"2026-04-01T10:14:09+00:00","description":"ClimaBarn ventilation in reclyning area ensure cool, draft-free airflow in cow farms, boosting comfort and supporting higher milk yields.","breadcrumb":{"@id":"https:\/\/www.climabarn.de\/en\/barn-ventilation\/ventilation-in-reclyning-area\/#breadcrumb"},"inLanguage":"en","potentialAction":[{"@type":"ReadAction","target":["https:\/\/www.climabarn.de\/en\/barn-ventilation\/ventilation-in-reclyning-area\/"]}]},{"@type":"ImageObject","inLanguage":"en","@id":"https:\/\/www.climabarn.de\/en\/barn-ventilation\/ventilation-in-reclyning-area\/#primaryimage","url":"https:\/\/www.climabarn.de\/en\/wp-content\/uploads\/sites\/22\/2025\/08\/AdobeStock_899378495-scaled-e1756788336307.webp","contentUrl":"https:\/\/www.climabarn.de\/en\/wp-content\/uploads\/sites\/22\/2025\/08\/AdobeStock_899378495-scaled-e1756788336307.webp","width":2560,"height":1058,"caption":"A group of black and white dairy cows lies comfortably on a smooth concrete floor inside a spacious barn designed for livestock. The cows are dispersed in a neat row, highlighting their calm demeanor in the well-lit environment."},{"@type":"BreadcrumbList","@id":"https:\/\/www.climabarn.de\/en\/barn-ventilation\/ventilation-in-reclyning-area\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/www.climabarn.de\/en\/"},{"@type":"ListItem","position":2,"name":"Barn Ventilation","item":"https:\/\/www.climabarn.de\/en\/barn-ventilation\/"},{"@type":"ListItem","position":3,"name":"Reclyning Area"}]}]}},"_links":{"self":[{"href":"https:\/\/www.climabarn.de\/en\/wp-json\/wp\/v2\/pages\/9640","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.climabarn.de\/en\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/www.climabarn.de\/en\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/www.climabarn.de\/en\/wp-json\/wp\/v2\/users\/8"}],"replies":[{"embeddable":true,"href":"https:\/\/www.climabarn.de\/en\/wp-json\/wp\/v2\/comments?post=9640"}],"version-history":[{"count":10,"href":"https:\/\/www.climabarn.de\/en\/wp-json\/wp\/v2\/pages\/9640\/revisions"}],"predecessor-version":[{"id":9982,"href":"https:\/\/www.climabarn.de\/en\/wp-json\/wp\/v2\/pages\/9640\/revisions\/9982"}],"up":[{"embeddable":true,"href":"https:\/\/www.climabarn.de\/en\/wp-json\/wp\/v2\/pages\/9043"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.climabarn.de\/en\/wp-json\/wp\/v2\/media\/9618"}],"wp:attachment":[{"href":"https:\/\/www.climabarn.de\/en\/wp-json\/wp\/v2\/media?parent=9640"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}